What are the contact forms of the relay

Update:23-08-2022
A relay is an electrical control device, which is an electrical appliance that makes a predetermined step change in the controlled quantity in the electrical output circuit when the change of the input quantity (excitation quantity) reaches three-phase relay the specified requirements. It has an interactive relationship between the control system (also known as the input loop) and the controlled system (also known as the output loop). Usually used in automated control circuits, it is actually an "automatic switch" that uses a small current to control the operation of a large current. Therefore, it plays the role of automatic adjustment, safety protection, and conversion circuit in the circuit.

Custom RoHS & UC3 Certification 120A Three Phase Latching Relays
Character:
-120A three sets of contacts switching capability.
-Only impulse excitation needed, both for single and double coil.
-Low power consumption, small in size
-Custom assemblies available with flexible wire and/or copper straps,and/or with integrated shunt
-4KV dielectric strength between coil and contacts
-RoHS compliant
-IEC62055-31 UC3 compliant
-Outline dimensions: (103 x 46.5 x 41.7) mm

There are three basic forms of relay contacts:
1. The two contacts of the moving type (normally open) coil are disconnected when the coil is not energized, and the two contacts are closed when the coil is energized. It is represented by the pinyin prefix "H" of the ligature, and the letter "M" is represented in the selection number of the Yongneng relay.
2. The two contacts are closed when the coil is not energized, and the two contacts are disconnected when the coil is energized. It is represented by the phonetic prefix "D" of the hyphenated word, and the letter "B" is represented in the selection number of the permanent energy relay.
3. Conversion type This is the contact group type. This kind of contact group has three contacts in total, that is, the middle is a moving contact, and the upper and lower are a static contact. When the coil is not energized, the moving contact and one of the static contacts are disconnected and the other is closed. After the coil is energized, the moving contact will move, so that the original open is closed, and the original closed is in an open state. Purpose. Such contact groups are called changeover contacts. It is represented by the pinyin prefix "z" of the word "zhuan", and there is no letter in the selection number of the Yongneng relay to indicate the conversion type.
Hot Sale GRT508H-120A Single-phase relay

Hot Sale GRT508H-120A Single-phase relay

Character: -120A contact switching capability.-Only impulse excitation needed, both for single and ...

View More
Custom 90A Low power consumption Single-phase relay

Custom 90A Low power consumption Single-phase relay

Character: -90A contact switching capability.-Only impulse excitation needed, both for single and d...

View More
100A UC3 & RoHS compliant Two-phase Relay

100A UC3 & RoHS compliant Two-phase Relay

Character: -100A two sets of contact switching capability.-Only impulse excitation needed, both for...

View More
RoHS compliant 25A PCB type Smart Home relay

RoHS compliant 25A PCB type Smart Home relay

Character: -25A contacts switching capability.-Only impulse excitation needed, both for single and ...

View More
UC 2 Compliant 80A Three-phase Latching Relay

UC 2 Compliant 80A Three-phase Latching Relay

Character: -80A three sets of contacts switching simultaneously, auxiliary contact can be added.-On...

View More